INSTALLATION AND OPERATION INSTRUCTIONS
INSTALLATION AND OPERATION INSTRUCTIONSINSTALLATION AND OPERATION INSTRUCTIONS
INSTALLATION AND OPERATION INSTRUCTIONS
FOR THE
FOR THEFOR THE
FOR THE
MODEL
MODELMODEL
MODEL
SW 2000
SW 2000 SW 2000
SW 2000
-
--
-
B1
B1B1
B1
SWING GATE OPERATOR
SWING GATE OPERATORSWING GATE OPERATOR
SWING GATE OPERATOR
(
((
(-
--
-68 BOARD)
68 BOARD)68 BOARD)
68 BOARD)
Zobrazit stránku 0
1 2 3 4 5 6 ... 53 54

Shrnutí obsahu

Strany 1 - MODELMODEL

Doc 6001242 (01Doc 6001242 (01Doc 6001242 (01Doc 6001242 (01----20273)20273)20273)20273) Rev CRev CRev CRev C

Strany 2 - TABLE OF CONTENTS

Rev C Doc 6001242 (01-20273) 9 of 53 C. RUNNING INPUT WIRING 1. Remove the plastic control box cover. 2. Run wires from input components and Mast

Strany 3

10 of 53 Doc 6001242 (01-20273) Rev C F. USING MANUAL CONTROLS Figure 5. Manual Controls, Location and Use. Use the manual controls on Manual Inp

Strany 4 - WARNING!

Rev C Doc 6001242 (01-20273) 11 of 53 G. GATE ARM INSTALLATION Figure 6. Gate Arm Installation. 1. Attach gate anchor to gate by welding or usi

Strany 5

12 of 53 Doc 6001242 (01-20273) Rev C H. SETTING LIMIT CAMS • The limit cams are adjusted by loosening the locking screws and rotating the cams.

Strany 6 - SITE PREPARATION

Rev C Doc 6001242 (01-20273) 13 of 53 2. SETTING LEFT GATE LIMIT CAMS Figure 8. Setting Left Gate Limit Cam. 1. Make sure that switch S2 is set

Strany 7

14 of 53 Doc 6001242 (01-20273) Rev C I. GATE SENSITIVITY ADJUSTMENTS The gate operator monitors both average and peak motor current. When the ga

Strany 8 - INSTALLATION NOTES

Rev C Doc 6001242 (01-20273) 15 of 53 2. RIGHT GATE (COUNTERCLOCKWISE OPEN) ADJUSTMENTS "Left Reverse" Adjustment (R81) 1. Initiate open

Strany 9 - SYSTEM INSTALLATION

16 of 53 Doc 6001242 (01-20273) Rev C J. SETTING GATE CONTROL SWITCH S1 AND RECLOSE TIMER POT R94 NOTE: For complete details on controls, indicato

Strany 10

Rev C Doc 6001242 (01-20273) 17 of 53 2. RECLOSE TIMER ENABLE (S1) AND SET (R94) Figure 11. Reclose Timer Enable and Adjustmment Location. The Re

Strany 11

18 of 53 Doc 6001242 (01-20273) Rev C K. POWER FAIL OPERATION OPTION CONNECTION a) Power Fail Operation Option Connection CAUTION Perform the next

Strany 12

Rev C Doc 6001242 (01-20273) 1 of 53 TABLE OF CONTENTS SAFETY SUMMARY...

Strany 13

Rev C Doc 6001242 (01-20273) 19 of 53 L. CONNECTING INPUT WIRING Figure 12. Control Board Wiring. 1. Remove the plastic control box cover. See

Strany 14

20 of 53 Doc 6001242 (01-20273) Rev C NOTES 1. Disconnecting the STOP terminal from the COMMON terminal stops the gate and prevents all commands fr

Strany 15

Rev C Doc 6001242 (01-20273) 21 of 53 5. Maximum Retry Count 1. If you want the gate to resume operation automatically up to 2 times, 30 seconds a

Strany 16

22 of 53 Doc 6001242 (01-20273) Rev C 10. Shadow Loop 1. Ensure the gate is fully closed (the close limit switch and Maglock LED’s will be ON). 2.

Strany 17 - SLIDE and ATG ON:

Rev C Doc 6001242 (01-20273) 23 of 53 N. FINAL ASSEMBLY OF GATE OPERATOR Figure 13. Gate Operator Final Assembly. IMPORTANT SAFETY PROCEDURE ⇒ I

Strany 18

24 of 53 Doc 6001242 (01-20273) Rev C PART 3 MASTER/SLAVE OPERATION A. WHAT IS MASTER/SLAVE OPERATION? The easy way to understand master/slave o

Strany 19

Rev C Doc 6001242 (01-20273) 25 of 53 C. MASTER/SLAVE WIRING Connecting Master and Slave units is fast and easy: • Master/Slave connections are m

Strany 20

26 of 53 Doc 6001242 (01-20273) Rev C D. MASTER/SLAVE SETUP PROCEDURE 1. Be sure to turn off both gate operator units. 2. Connect Master and Slav

Strany 21

Rev C Doc 6001242 (01-20273) 27 of 53 E. MASTER/SLAVE INSTALLATION DETAILS 1. BI-PARTING GATE DETAILS The simple Bi-Parting Gate is typically used

Strany 22

28 of 53 Doc 6001242 (01-20273) Rev C 2. BI-PARTING LATCH GATE DETAILS The Bi-Parting Latch Gate is typically used in low traffic residential sites

Strany 23

2 of 53 Doc 6001242 (01-20273) Rev C The LiftMaster Model SW 2000-B1 The LiftMaster model SW 2000-B1 Swing Gate Operator is a full featured commer

Strany 24

Rev C Doc 6001242 (01-20273) 29 of 53 3. TRAP GATE DETAILS The Trap gate is typically used in secured sites for screening incoming and/or outgoing

Strany 25 - MASTER/SLAVE OPERATION

30 of 53 Doc 6001242 (01-20273) Rev C There are 2 different ways to close the gate (entering or exiting): 1. Reclose Timer: When the Reclose Timer

Strany 26

Rev C Doc 6001242 (01-20273) 31 of 53 4. TANDEM GATE DETAILS The Tandem gate is typically used in high traffic situations where some control of inc

Strany 27

32 of 53 Doc 6001242 (01-20273) Rev C • A continuous FIRE input in either gate opens both gates and holds them open. • A continuous Manual STOP in

Strany 28 - For safety, setting MUST

Rev C Doc 6001242 (01-20273) 33 of 53 PART 4 MODEL SW 2000-B1 OPTIONS A. LIFTMASTER LOOP DETECTOR BOARDS The model SW 2000-B1 has connectors for

Strany 29

34 of 53 Doc 6001242 (01-20273) Rev C PART 5 TROUBLESHOOTING AND MAINTENANCE A. TROUBLESHOOTING This section is designed to help you troubleshoot

Strany 30

Rev C Doc 6001242 (01-20273) 35 of 53 3. MOTOR DOES NOT RUN Motor is dead: 1. The resettable motor thermal overload switch has popped. 2. The int

Strany 31

36 of 53 Doc 6001242 (01-20273) Rev C 10. GATE DOESN'T STOP AT THE LIMIT 1. Limit cams are out off adjustments. 2. Limit switch cable is dis

Strany 32

Rev C Doc 6001242 (01-20273) 37 of 53 19. GATE DOES NOT MOVE AFTER POWER OUTAGE 1. Bad Power Fail Option battery. 2. Miswired DC motor inputs. 3.

Strany 33

38 of 53 Doc 6001242 (01-20273) Rev C 26. SHADOW LOOP IS INEFFECTIVE 1. The gate is not at either the open or close limit. 2. Bad loop sensor or

Strany 34 - MODEL SW 2000-B1 OPTIONS

Rev C Doc 6001242 (01-20273) 3 of 53 SAFETY SUMMARY It is important for everyone involved in the installation and operation of the LiftMaster model

Strany 35 - PART 5

Rev C Doc 6001242 (01-20273) 39 of 53 C. FAULTS AND THEIR CAUSES 1. IF FAULT AND OVERLOAD LED’S ARE TURNED ON 1. OVERLOAD adjustment is set too l

Strany 36

40 of 53 Doc 6001242 (01-20273) Rev C D. MAINTENANCE WARNING To avoid injury, always turn off the unit power switch before working on gate. Regularl

Strany 37

Rev C Doc 6001242 (01-20273) 41 of 53 PREVENTIVE MAINTENANCE INSTRUCTIONS Figure 20. Gate Operator Disassembly and Assembly. Gate Operator Serial

Strany 38

42 of 53 Doc 6001242 (01-20273) Rev C The following table was provided to help you keep a record of the maintenance schedule. Write the inspection

Strany 39

Rev C Doc 6001242 (01-20273) 43 of 53 APPENDIX A SYSTEM OPERATION REFERENCE CONTROLS, INDICATORS, INPUTS AND ADJUSTMENTS For control and indicato

Strany 40

44 of 53 Doc 6001242 (01-20273) Rev C CONTROLS SWITCH S1 (OFF/ON DIP SWITCH) SLIDE ACTION When used with ATG, this switch controls several gate oper

Strany 41 - WARNING

Rev C Doc 6001242 (01-20273) 45 of 53 TIMER Indicates the Reclose Timer is running. Timer is set at pot R94. FAULT Indicates a fault in the syste

Strany 42

46 of 53 Doc 6001242 (01-20273) Rev C SHADOW LOOP Activation prevents the gate from opening or closing so the gate won't hit a vehicle. If th

Strany 43 - MAINTENANCE SCHEDULE TABLE

Rev C Doc 6001242 (01-20273) 47 of 53 INS./OUTS. INT. SENSE / SHADOW SENSE / EXIT SENSE (TB12/TB13/TB14/TB15) INPUTS INSIDE Input from an Inside In

Strany 44 - SYSTEM OPERATION REFERENCE

48 of 53 Doc 6001242 (01-20273) Rev C CONNECTORS LIMIT SWITCH (J4) Connector for the left/right limit switch cable. BATTERY I/O (J11) Connector fo

Strany 45

4 of 53 Doc 6001242 (01-20273) Rev C BASIC INSTALLATION HINTS AND RULES PLEASE READ THIS SECTION CAREFULLY BEFORE BEGINNING YOUR INSTALLATION. The s

Strany 46

Rev C Doc 6001242 (01-20273) 49 of 53 APPENDIX B PARALLEL GATE WIRING While it is strongly recommended that the Master/Slave function be used in

Strany 47

50 of 53 Doc 6001242 (01-20273) Rev C APPENDIX C MODEL SW 2000-B1 PARTS LIST ITEM # PART NAME WHAT IT DOES 1 Control Box/Clear Cover Contain

Strany 48

Rev C Doc 6001242 (01-20273) 51 of 53 GLOSSARY AC: Alternating Current. An electric current or voltage that reverses direction at regular interva

Strany 49

52 of 53 Doc 6001242 (01-20273) Rev C NOTICE TO CANADIAN USERS NOTICE: The Industry Canada label identifies certified equipment. This certification

Strany 50 - PARALLEL GATE WIRING

COPYRIGHT 2001 ALL RIGHTS RESERVED This document is protected by copyright and may not be copied or adapted without the prior written consent

Strany 51 - MODEL SW 2000-B1 PARTS LIST

Rev C Doc 6001242 (01-20273) 5 of 53 PART 1 SITE PREPARATION A. LOCATION AND LAYOUT Figure 1. Gate Operator Layout Options. NOTES • Left Gate

Strany 52 - GLOSSARY

6 of 53 Doc 6001242 (01-20273) Rev C B. PAD AND MOUNT Figure 2. Pad and Mount. 1. The concrete pad must be sufficient to support the gate operat

Strany 53 - NOTICE TO CANADIAN USERS

Rev C Doc 6001242 (01-20273) 7 of 53 C. POWER WIRING 1. Provide a separate conduit stub for the AC power. 2. Each gate operator requires a 115 VAC

Strany 54

8 of 53 Doc 6001242 (01-20273) Rev C PART 2 SYSTEM INSTALLATION A. MOUNTING GATE OPERATOR WARNING For safety reasons, the Power Fail Operation O